Description
- Brand Name: LanYuXuan
- Certification: NONE
- Origin: CN(Origin)
- Warranty: 3 years
- Certification: scoc
- Customized support: OEM, ODM, OBM
- Place of Origin: Guangdong, China
- Brand Name: Cancare
- Model Number: CCL-5800
- Size: 460*360*225mm
- Weight: 18kg
- Focal Length: N/A
- Wavelength Range: 190-1100nm, 190-1100nm
- Name: spectrophotometer device
- Bandwidth: 1.8nm
- Wavelength Accuracy: ±0.3nm
- Wavelength Repeatability: 0.1nm
- Photometric Accuracy: ±0.05%T
- Photometric Repeatability: 0.2%T
- Photometric Range: -0.3-3A,0-200%T,0-9999C
- Data Output Port: USB
- Detector: Silicon Photodiode
#detail_decorate_root .magic-0{border-bottom-style:solid;border-bottom-color:#53647a;font-family:Roboto;font-size:24px;color:#53647a;font-style:normal;border-bottom-width:2px;padding-top:8px;padding-bottom:4px}#detail_decorate_root .magic-1{vertical-align:top}#detail_decorate_root .magic-2{vertical-align:top;display:block;padding-right:4px;box-sizing:border-box;padding-left:4px}#detail_decorate_root .magic-3{vertical-align:top;padding-bottom:4px;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-4{padding:0;margin:0;white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-5{font-size:18px}#detail_decorate_root .magic-7{font-size:16px}#detail_decorate_root .magic-8{width:750px;border-collapse:collapse}#detail_decorate_root .magic-9{min-height:18px;padding:5px 10px;width:126px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-10{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-11{vertical-align:top;display:inline-block;padding-right:4px;width:33.33%;box-sizing:border-box;margin-bottom:-4px;padding-left:4px;margin-top:-4px}#detail_decorate_root .magic-12{vertical-align:top;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-13{width:245px;height:326.6666666666667px;overflow:hidden}#detail_decorate_root .magic-14{position:relative;left:0;top:0;width:245px;height:326.6666666666667px}#detail_decorate_root .magic-15{width:245px;height:326px;overflow:hidden}#detail_decorate_root .magic-16{width:750px}#detail_decorate_root .magic-17{overflow:hidden;width:184.5px;height:401.0869565217392px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-18{margin-top:0;margin-left:0;width:184px;height:401px}#detail_decorate_root .magic-19{overflow:hidden;width:184.5px;height:401.0869565217392px;margin-top:0;margin-bottom:0;margin-left:4px;margin-right:0}#detail_decorate_root .magic-20{text-align:center}#detail_decorate_root .magic-21{font-size:28px}#detail_decorate_root .magic-22{color:#333;font-family:arial,helvetica,sans-serif;font-size:14px;font-style:normal;font-variant-ligatures:normal;font-variant-caps:normal;font-weight:400;letter-spacing:normal;orphans:2;text-align:start;text-indent:0;text-transform:none;white-space:normal;widows:2;word-spacing:0;-webkit-text-stroke-width:0;background-color:#fff;text-decoration-style:initial;text-decoration-color:initial;display:inline !important;float:none}#detail_decorate_root .magic-23{color:#333;font-family:arial,helvetica,sans-serif;font-size:14px;font-style:normal;font-variant-ligatures:normal;font-variant-caps:normal;letter-spacing:normal;orphans:2;text-align:start;text-indent:0;text-transform:none;white-space:normal;widows:2;word-spacing:0;-webkit-text-stroke-width:0;background-color:#fff;text-decoration-style:initial;text-decoration-color:initial;float:none;display:inline !important}#detail_decorate_root .magic-24{width:245px;height:245px;overflow:hidden}#detail_decorate_root .magic-25{position:relative;left:0;top:0;width:245px;height:245px}#detail_decorate_root .magic-26{position:relative;left:4px;top:86px;width:241px;height:152px}#detail_decorate_root .magic-27{position:relative;left:2px;top:10px;width:245px;height:245px}#detail_decorate_root .magic-28{width:446px}#detail_decorate_root .magic-29{overflow:hidden;width:446px;height:400px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-30{margin-top:0;margin-left:0;width:446px;height:400px}#detail_decorate_root .magic-31{width:300px;display:flex;flex-direction:column;margin-right:0;margin-left:4px}#detail_decorate_root .magic-32{overflow:hidden;width:750px;height:400px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-33{margin-top:0;margin-left:0;width:750px;height:400px}
Features
The instrument uses a lead screw structure so that the instrument wavelength accuracy and wavelength resolution can be greatly
improved.
Auto setting wavelength
Users set wavelength automatically through arrow keys to avoid operation errors.
Numerical Keys
With microprocessor controlled, all parameters of the instrument can be easily set by numerical keys.
Date output
Equipped with USB port to connect with a PC to display spectrum scanning, kinetics and multi wavelength testing results on the
screen through the optional software.
8mm thick optical base
The instrument use a rigid die-cast aluminum base as its optical mount to ensure instrument stability and reliability.
Imported high quality deuterium lamp
The UV instruments use imported flanged deuterium lamp with low stray light, pohotmetric accuracy and easy replacing.
Standard curve
instruments can set up various standard curves according to customer’s solutions and find the concentration of unknown solutions.
Details Images
Features
The instrument uses a lead screw structure so that the instrument wavelength accuracy and wavelength resolution can be greatly
improved.
Auto setting wavelength
Users set wavelength automatically through arrow keys to avoid operation errors.
Numerical Keys
With microprocessor controlled, all parameters of the instrument can be easily set by numerical keys.
Date output
Equipped with USB port to connect with a PC to display spectrum scanning, kinetics and multi wavelength testing results on the
screen through the optional software.
8mm thick optical base
The instrument use a rigid die-cast aluminum base as its optical mount to ensure instrument stability and reliability.
Imported high quality deuterium lamp
The UV instruments use imported flanged deuterium lamp with low stray light, pohotmetric accuracy and easy replacing.
Standard curve
instruments can set up various standard curves according to customer’s solutions and find the concentration of unknown solutions.
Model
|
CCL-5800
|
Wavelength Range
|
190-1100nm
|
Bandwidth
|
2nm
|
Wavelength Accuracy
|
±0.5nm
|
Wavelength Repeatability
|
0.2nm
|
Wavelength Setting
|
Auto
|
Photometric Accuracy
|
±0.3%T
|
Photometric Repeatability
|
0.2%T
|
Photometric Range
|
-0.3-3A
0-200%T 0-9999C |
Stability
|
± 0.001A/h @ 500nm
|
Baseline Flatness
|
± 0.0015A/h
|
Stray Light
|
≤0.05%T
|
Data Output Port
|
USB
|
Printer Port
|
Parallel Port
|
Display
|
128*64 Dots LCD
|
Lamps
|
W Lamp/D2&W Lamp
|
Detector
|
Silicon Photodiode
|
Power Requirements
|
AC 220V/50Hz or 110V/60Hz
|
Dimension
|
460*360*225mm
|
Weight
|
18kg
|
Certifications
CE certificate
ISO certificate
CO certificate
Customer Photos
Why Choose Us
Post Service: we have partners in your local country,we can support you installation, maintenance and other Local Post service.
Cost Efficient Price: We compared many different models, offer best choice for you.
Fast Shopping: we offer one stop for medical items, from machine to disposable items.
Customs clearance: we offer support for your native countries customs clerance.
and more others
Recommend Products
Cliick Following Picture to return back to relative product catalog.
Oven
Elisa Analyzer
Consumable
FAQ
Q1:How to make sure your payment safe?
A:We will send the proforma invoice with our company bank information by email,and we will also verify bank information by whatsapp, viber, phone and other ways. your deal will be protected by Alibaba and you can complain to Alibaba if we haven’t finished your order well.
Q2:How can you get quotation quickly?
A:You can contact us by whatsapp, skype, viber or phone and we will response you within several minutes . Email is not he best choice because of its low interaction. and we will response your email within 24 hours.
Q3:How about the package and shipping?
A:all packed by strong exporting wooden and carton package. you can ship by our agent or your own agent.
Contact Us
China Care Medical Equipment Co.,Ltd
Joseph Zhou
Product Manager
Whatspp:
+8613926480041
+8613926480041
Skype: chinacaremed
Web: www.chinacaremedical.com
Email: joseph@chinacaremedical.com