Description
- Brand Name: NoEnName_Null
- DIY Supplies: ELECTRICAL
- Display Type: Digital Only
- Operating Temperature: – 10 ~50 below 80% RH
- Model Number: ETCR3440A
- Accuracy Class: 5% 10V
- Testing Voltage: 5KV
- Dimensions: 35cm*28cm *18cm
- Measuring Range: 0.5KV-5KV
1.Product function:
Be used forInsulation resistance test of cable, motor, generator, transformer, transformer, high voltage switch, lightning arrester and other large equipment.
2.Product characteristics:
OneHigh resolution LCD display, full Chinese operation interface, clear and convenient reading, high resolution LCD, full Chinese operation interface, reading clear and convenient.
TwoAutomatic calculation of absorption ratio and polarization index and automatic storageThe minute-to-minute data of 15 seconds, 1 minute and 10 minutes are easy to analyze.
ThreeThe output current is larger than the short circuit current.5mA.
FourIt has strong anti-interference ability and can meet the field operation of UHV substation.
FiveThe automatic discharge is completed and the discharge process is monitored in real time.
SixWith rechargeable batteries and chargers, full charge can be used continuously when backlight is not used.6~12 hours
3.Specification:
Model |
Insulation Resistance Range |
Test voltage |
short-circuit current |
Absorption Ratio and Polarization Index |
ETCR3440A |
0.1M~400G_ |
5KV |
>5mA |
Yes |
Main technical performance |
|
Gong Neng |
Measurement of Insulation Resistance |
Accuracy |
(10%+5) |
measuring range |
0.1M~400G_ |
Test voltage |
Setting range: 0.5KV-5KV; Accuracy: 5%+10V |
short-circuit current |
>5mA |
Automatic calculation of absorption ratio And polarization index |
Yes |
Charging function |
Yes, it can be used continuously for 6 to 12 hours when it is full of electricity. |
Measuring time |
1-10 minutes (depending on the measurement method) |
Charging power supply |
180-270 VAC, 50 Hz/60 Hz + 1% (municipal or generator power supply) |
Instrument size |
35cm (long)X28cm (wide)X18cm (high) |
Instrument weight |
5kg (No Cable Package) |
Working temperature and humidity |
– 10 ~50 below 80% RH |
Storage temperature and humidity |
– 20-60 below 70% RH |
insulation resistance |
50M(1000v) (between measuring circuit and outer shell) |
Pressure resistance |
AC 3KV 50Hz 1min (between measuring circuit and shell) |
Anti-jamming ability |
5000v Induction Electricity |
Random attachment |
Host1; test line; 3; power cord: 1; toolkit: 1; instruction and certificate: 1 |
Z.L.T