Description
- Brand Name: laserlands
- Certification: NONE
- Origin: CN(Origin)
- Style: Mini
- Power: Other
- Model Number: PLT5 510 with PD
- Voltage: 3V
- Occasion: Home Entertainment
510nm 515nm 10mw PLT5 510 Green Laser Diode LD with PD for Laser Level with PD
Osram 510nm PLT5 510 with PD
Features
• Optical output power (continuous wave): 10 mW (Tcase = 25 °C)
• Typical emission wavelength: 515 nm
• Efficient radiation source for cw and pulsed operation
• Single transverse mode semiconductor laser
• High modulation bandwidth
• TO56 package with photo diode
Applications
• Laser projection
• Laser shows
• Presenter
• Biomedical Applications
• Metrology
Safety Advice
Depending on the mode of operation, these devices emit highly concentrated visible light which can be hazardous to the human eye. Products which incorporate these devices have to follow the safety precautions found in IEC 60825-1 “Safety of laser products”.
Optical Output Power Popt (Tcase = 25°C) |
Ordering Code |
|
PLT5 510_B1-3 |
10 mW |
Q65111A6310 |
Maximum Ratings
Operation outside these conditions may damage the device. Operation at the maximum ratings influences lifetime.
Parameter |
Symbol |
Values |
Unit |
|
min. |
max. |
|||
Operating Current |
IF |
120 |
mA |
|
Operating Temperature |
Tcase |
-20 |
+60 |
°C |
Storage Temperature |
Tstg |
-40 |
+85 |
°C |
Reverse Voltage |
VR |
2 |
V |
|
Soldering Temperature max. 10 sec. |
Tsolder |
260 |
°C |
|
Junction temperature |
Tj |
120 |
°C |
Laser Characteristics (Tcase = 25 °C)
Parameter |
Symbol |
Values |
Unit |
||
min. |
typ. |
max. |
|||
Emission Wavelength 1) B1 B2 B3 |
λpeak |
510 515 520 |
– – – |
515 520 530 |
nm |
Spectral Width (FWHM) 1) |
Δλ |
– |
2 |
– |
nm |
Threshold Current |
Ith |
– |
30 |
60 |
mA |
Operating Current 1) |
IF |
– |
60 |
100 |
mA |
Operating Voltage 1) |
VF |
– |
5.4 |
7.0 |
V |
Beam Divergence (FWHM) 1) |
θ∥ x θ⊥ |
5 x 19 |
6.6 x 21.4 |
9 x 25 |
deg |
Polarization 1) |
Pgr |
– |
100:1 |
– |
|
Modulation Frequency |
f |
– |
>100 |
– |
MHz |
Thermal resistance (junction to case) |
Rth |
– |
34 |
– |
K/W |
Monitor current 1) 2) |
Im |
– |
150 |
– |
µA |
1) Standard operating conditions refer to a continuous wave output power of Popt = 10 mW.
2) Photo current refers to a reverse voltage of VR = 5 V.
Reviews