Description
- Brand Name: Hantek
- Certification: CE
- DIY Supplies: ELECTRICAL
- Origin: Mainland China
- Model Number: DSO5062B
- Display Resolution: 800*480 Pixels
- IS Battery Demountable: No
- Band Width: 60MHz
- Record Length: 1M
- Display Size: 7 Inches & Above
- Real Time Sampling Rate: 1GSa/S
- Equivalent Sample: 25GS/s
Hantek DSO5062B Digital Benchtop Oscilloscope 60MHz Bandwidth Provides Software for PC Real-time Analysis
Feature
-
60MHz bandwidths.
-
1GSa/s Real Time sample rate
-
Large (7.0-inch) color display,WVGA(800×480)
-
Record length up to 1M
-
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
-
USB host and device connectivity, standard
-
Multiple automatic measurements
-
Four math functions, including FFTs standard
-
Provides software for PC real-time analysis
-
VGA (Optional Function)
Parameter
hantek oscilloscope Model |
DSO5062B |
|||
Acquisition |
||||
Sample Rate |
Real-Time Sample: 1GS/s |
|||
Acquisition Modes |
||||
Normal |
Normal data only |
|||
Peak Detect |
High-frequency and randon glith capture |
|||
Average |
Wavefom Average, selectable 4,8,16,32,64,128 |
|||
Inputs |
||||
Inputs Coupling |
AC, DC, GND |
|||
Inpits Impendance |
1MΩ±2% //20pF±3pF |
|||
Probe Attenuation |
1X, 10X |
|||
Supported Probe Attenuation Factor |
1X, 10X, 100X, 1000X |
|||
Maximum Input Voltage |
CAT I and CAT II: 300VRMS (10×), Installation Category; |
|||
Horizontal |
||||
Sample Rate Range |
500MS/s–1GS/s |
|||
Waveform Interpolation |
(sin x)/x |
|||
Record Length |
Maximum 1M samples per single-channel; |
|||
SEC/DIV Range |
2ns/div to 40s/div |
4ns/div to 40s/div |
||
Sample Rate and |
±50ppm (at over any ≥1ms time interval) |
|||
Position Range |
2ns/div to 10ns/div; |
20ns/div to 80us/div; (-8div x s/div) to 40ms; |
||
Delta Time Measurement Accuracy |
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); |
|||
Vertical |
||||
Vertical Resolution |
8-bit resolution, all channel sampled simultaneously |
|||
Position Range |
2mV/div to 200mV/div, ±2V |
|||
Bandwidth |
200MHz |
100MHz |
60MHz |
|
Rise Time at BNC( typical) |
1.8ns |
3.5ns |
5.8ns |
|
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled |
2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V |
|||
Math |
+, -, *, /, FFT |
|||
FFT |
Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; |
|||
Bandwidth Limit |
20MHz |
|||
Low Frequency Response (-3db) |
≤10Hz at BNC |
|||
DC Gain Accuracy |
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; |
|||
DC Measurement Accuracy, |
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; |
|||
Volts Measurement Repeatability, |
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |
|||
Trigger System |
||||
Trigger Types |
Edge, Video, Pulse, Slope, Over time, Alternative |
|||
Trigger Source |
CH1, CH2, EXT, EXT/5, AC Line |
|||
Trigger Modes |
Auto, Normal, Single |
|||
Coupling Type |
DC, AC, Noise Reject, HF Reject, LF Reject |
|||
Trigger Sensitivity |
DC(CH1,CH2): |
|||
Trigger Level Range |
CH1/CH2: ±8 divisions from center of screen; |
|||
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns |
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; |
|||
Set Level to 50%(typical) |
Operates with input signals ≥50Hz |
|||
Video Trigger |
||||
Video Trigger Type |
CH1, CH2: Peak-to-peak amplitude of 2 divisions; |
|||
Signal Formats and Field Rates, Video Trigger Type |
Supports NTSC, PAL and SECAM broadcast systems for any field or any line |
|||
Holdoff Range |
100ns ~ 10s |
|||
Pulse Width Trigger |
||||
Pulse Width Trigger Mode |
Trigger when (, = , or ≠); Positive pulse or Negative pulse |
|||
Pulse Width Trigger Point |
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. |
|||
Pulse Width Range |
20ns ~ 10s |
|||
Slope Trigger |
||||
Slope Trigger Mode |
Trigger when ( , = , or ≠ ); Positive slope or Negative slope |
|||
Slope Trigger Point |
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. |
|||
Time Range |
20ns ~ 10s |
|||
Overtime Trigger |
||||
Over Time Mode |
Rising edge or Falling edge |
|||
Time Range |
20ns ~ 10s |
|||
Alternative Trigger |
||||
Trigger on CH1 |
Internal Trigger: Edge, Pulse Width, Video, Slope |
|||
Trigger on CH2 |
Internal Trigger: Edge, Pulse Width, Video, Slope |
|||
Trigger Frequency Counter |
||||
Readout Resolution |
6 digits |
|||
Accuracy (typical) |
±30ppm (including all frequency reference errors and ±1 count errors) |
|||
Frequency Range |
AC coupled, from 4Hz minimum to rated bandwidth |
|||
Signal Source |
Pulse Width or Edge Trigger modes: all available trigger sources |
|||
Measure |
||||
Cursor Measurement |
Voltage difference between cursors: ΔV |
|||
Auto Measuerment |
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF |
|||
Display |
||||
Display Type |
7 inch 64K color TFT (diagonal liquid crystal) |
|||
Display Resolution |
800 horizontal by 480 vertical pixels |
|||
Display Contrast |
Adjustable (16 gears) with the progress bar |
|||
Probe Compensator Output |
||||
Output Voltage( typical) |
About 5Vpp into ≥1MΩ load |
|||
Frequency(typical) |
1kHz |
|||
Power Supply |
||||
Supply Voltage |
100-120VACRMS(±10%), 45Hz to 440Hz, CAT II 120-240VACRMS(±10%), 45Hz to 66Hz, CAT II |
|||
Power Consumption |
<30W |
|||
Fuse |
2A, T rating, 250V |
|||
Environmental |
||||
Temperature |
Operating: 32~122oF (0~50oC); |
|||
Cooling Method |
Convection |
|||
Humidity |
+104oFor below (+40oC or below): ≤90% relative humidity; |
|||
Altitude |
Operating: Below 3,000m (10,000 feet); |
|||
Mechanical |
||||
Size |
Length 385mm, Width 200mm, Height 245mm |
|||
Weight |
3.5KG(with Packing); 2.08KG (without Packing) |