Description
- Brand Name: Hantek
- Certification: CE
- DIY Supplies: ELECTRICAL
- Origin: Mainland China
- Model Number: DSO4102S
- Record Length: 40K
- Display Resolution: 800*480 Pixels
- Display Size: 7 Inches & Above
- Max Waveform Capture Rate: 30,000wfm/s
- Band Width: 100-349MHz
- IS Battery Demountable: No
- Digital Channels: 2
- Real Time Sampling Rate: 1GSa/S
Hantek DSO4102S Digital Multimeter Oscilloscope USB 100MHz 2 Channels 7″ 64K TFT Arbitrary Waveform Osciloscopio Logic Analyzer
2 Channel Digital Oscilloscope. 1 Channel Arbitrary/Function Waveform Generator. The Keys for oscilloscope and waveform generator is separated for convenient to operate it simultaneously. Oscilloscope: 100MHz Bandwidth, 1GSa/s Sample Rate. 25MHz Arbitrary waveform generator, 12 bits resolution, 200MHz DDS, 7 inch 64K color LCD display, Resolution 800×480.
Features:
2 channel digital oscilloscope + arbitrary/function waveform generator + synchronizing signal + external trigger.
The keys for oscilloscope and waveform generator is separated for convenient to operate it simultaneously.
Large and clear display (7 inch 64K color LCD display, Resolution 800×480), more clear and realistic waveform.
Oscilloscope: 1GSa/s Sample Rate, 100MHz Bandwidth, more than 20 kinds of auto measurement functions.
Powerful trigger function: edge, video, pulse, slope, over time, alternative.
Arbitrary/function waveform generator: 25MHz, 12 bits resolution, 200MHz DDS, arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC is easy to simulate transducer.
Integrated USB Host, Support USB disk storage, USB interface/SD card system update.
Note:
Hantek DSO4102S Digital Oscilloscope is for 3 years Warranty!
Please read the instruction manual data CD carefully to avoid injury and prevent damage to this product.
Specifications:
Model |
DSO4102S |
||
Oscilloscope |
|||
Sample Rate |
Sampling Rate Range: 1GSa/s |
||
Equivalent Sample Rate: 25GSa/s |
|||
Acquisition Modes |
|||
Normal |
Normal data only |
||
Peak Detect |
High-frequency and randon glith capture |
||
Average |
Wavefom Average, selectable 4,8,16,32,64,128 |
||
Inputs |
|||
Inputs Coupling |
AC, DC, GND |
||
Inpits Impendance |
1MΩ±2% 20pF±3pF |
||
Probe Attenuation |
1X, 10X |
||
Supported Probe Attenuation Factor |
1X, 10X, 100X, 1000X |
||
Maximum Input Voltage |
CAT I and CAT II: 300VRMS (10×) |
||
CAT III: 150VRMS(1×); |
|||
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. |
|||
Horizontal |
|||
Sample Rate Range |
1GS/s |
||
Waveform Interpolation |
(sin x)/x |
||
Record Length |
40K |
||
SEC/DIV Range |
4ns/div to 40s/div |
||
Sample Rate and |
±50ppm(at over any ≥1ms time interval) |
||
Delay Time Accuracy |
|||
Position Range |
20ns/div to 80us/div; (-8div x s/div) to 40ms; |
||
200us/div to 40s/div; (-8div x s/div) to 400s |
|||
Delta Time Measurement Accuracy |
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); |
||
Vertical |
|||
Vertical Resolution |
8-bit resolution, all channel sampled simultaneously |
||
Position Range |
2mV/div to 10V/div |
||
Bandwidth |
100MHz |
||
Rise Time at BNC( typical) |
3.5ns |
||
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled |
2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±1V |
||
500mV/div to 2V/div, ±40V; 5V/div, ±50V |
|||
Math |
+, -, *, /, FFT |
||
FFT |
Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; |
||
1024 sample point |
|||
Bandwidth Limit |
20MHz |
||
Low Frequency Response (-3db) |
≤10Hz at BNC |
||
DC Gain Accuracy |
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; |
||
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div |
|||
DC Measurement Accuracy, |
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; |
||
Volts Measurement Repeatability, Average Acquisition Mode |
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |
||
Trigger System |
|||
Trigger Types |
Edge, Video, Pulse, Slope, Over time, Alternative |
||
Trigger Source |
CH1, CH2, EXT, EXT/5, AC Line |
||
Trigger Modes |
Auto, Normal, Single |
||
Coupling Type |
DC, AC, Noise Reject, HF Reject, LF Reject |
||
Trigger Sensitivity |
DC(CH1,CH2): |
||
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; |
|||
DC(EXT): |
|||
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; |
|||
DC(EXT/5): |
|||
1V from DC to 100MHz;1.75V from 100MHz to 200MHz; |
|||
AC: Attenuates signals below 10Hz; |
|||
HF Reject: Attenuates signals above 80kHz; |
|||
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz |
|||
Trigger Level Range |
CH1/CH2: ±8 divisions from center of screen; |
||
EXT: ±1.2V; |
|||
EXT/5:±6V |
|||
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns |
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; |
||
EXT: ± (6% of setting + 40mV); |
|||
EXT/5: ± (6% of setting + 200mV); |
|||
Set Level to 50%(typical) |
Operates with input signals ≥50Hz |
||
Video Trigger |
|||
Video Trigger Type |
CH1, CH2: Peak-to-peak amplitude of 2 divisions; |
||
EXT: 400mV; |
|||
EXT/5: 2V |
|||
Signal Formats and Field Rates, Video Trigger Type |
Supports NTSC, PAL and SECAM broadcast systems for any field or any line |
||
Holdoff Range |
100ns ~ 10s |
||
Pulse Width Trigger |
|||
Pulse Width Trigger Mode |
Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse |
||
Pulse Width Trigger Point |
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. |
||
Pulse Width Range |
20ns ~ 10s |
||
Slope Trigger |
|||
Slope Trigger Mode |
Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope |
||
Slope Trigger Point |
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. |
||
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. |
|||
Less than: The oscilloscope triggers when the waveform slope is less than the set slope. |
|||
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. |
|||
Time Range |
20ns ~ 10s |
||
Overtime Trigger |
|||
Over Time Mode |
Rising edge or Falling edge |
||
Time Range |
20ns ~ 10s |
||
Alternative Trigger |
|||
Trigger on CH1 |
Internal Trigger: Edge, Pulse Width, Video, Slope |
||
Trigger on CH2 |
Internal Trigger: Edge, Pulse Width, Video, Slope |
||
Trigger Frequency Counter |
|||
Readout Resolution |
6 digits |
||
Accuracy (typical) |
±30ppm (including all frequency reference errors and ±1 count errors) |
||
Frequency Range |
AC coupled, from 4Hz minimum to rated bandwidth |
||
Signal Source |
Pulse Width or Edge Trigger modes: all available trigger sources |
||
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. |
|||
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time. |
|||
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. |
|||
Video Trigger mode: The Frequency Counter does not work. |
|||
Measure |
|||
Cursor Measurement |
Voltage difference between cursors: V |
||
Time difference between cursors: T |
|||
Reciprocal of T in Hertz (1/ΔT) |
|||
Auto Measuerment |
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, |
||
+Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, |
|||
Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, |
|||
FRF, FFR, LRR, LRF, LFR, LFF |
|||
Signal Source Mode |
|||
Waveform Impedance |
DC-25MHz |
||
Sample Rate |
200MHzDDS |
||
Output Waveform |
Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC |
||
Frequency Resolution |
0.1% |
||
Waveform Depth |
2KSa |
||
Vertical Resolution |
12bit |
||
Frequency Stability |
<30ppm |
||
Waveform Range |
-3.5V~+3.5V |
||
Output Impedance |
50Ω |
||
Output Current |
50mA Ipeak=100mA |
||
System BW |
25M |
||
Harmonic Distortion |
-50dBc(1KHz),-40dBc(10KHz) |
||
General Features |
|||
Display |
|||
Display Type |
7 inch 64K color TFT (diagonal liquid crystal) |
||
Display Resolution |
800 horizontal by 480 vertical pixels |
||
Display Contrast |
Adjustable (16 gears) with the progress bar |
||
Probe Compensator Output |
|||
Output Voltage( typical) |
About 5Vpp into ≥1MΩ load |
||
Frequency(typical) |
1kHz |
||
Power Supply |
|||
Supply Voltage |
100-120VACRMS(±10%), 45Hz to 440Hz, CAT2 |
||
120-240VACRMS(±10%), 45Hz to 66Hz, CAT2 |
|||
Power Consumption |
<30W |
||
Fuse |
2A, T rating, 250V |
||
Environmental |
|||
Temperature |
Operating: 32 Fahrenheit to 122 Fahrenheit (0 to 50 Centigrade); |
||
Nonoperating: -40 Fahrenheit to 159.8 Fahrenheit(-40 Centigrade to +71Centigrade) |
|||
Cooling Method |
Convection |
||
Humidity |
+104 Fahrenheit or below (+40 Centigrade or below): ≤90% relative humidity; |
||
106 Fahrenheit to 122 Fahrenheit (+41 Centigrade to 50 Centigrade): ≤60% relative humidity |
|||
Altitude |
Operating: Below 3,000m (10,000 feet); |
||
Nonoperaring: Below 15,000m(50,000 feet) |
|||
Mechanical |
|||
Package Size |
Length 385mm, Width 200mm, Height 245mm |
||
Weight |
3.0KG(with Packing); 2.06KG(without Packing) |
Material: ABS
Bandwidth: 100MHz
Plug Type: EU / US (Optional)
Power Supply: AC220V~240V 50Hz / AC100~120V 60Hz
Oscilloscope Probe Model: PP-150
Length of the Powerline: Approx. 150cm / 59.1in
Length of the USB Line: Approx. 107cm / 42.1in
Length of the Probe Line: Approx. 130cm / 51.2in
Size of the Oscilloscope Body: Approx. 31.5 * 12 * 15cm / 12.4 * 4.7 * 5.9in (L * W * H)
Oscilloscope Weight: 2.06kg/ 4.6lb
Package Size: Approx. 38.5 * 19.5 * 24cm / 15.1 * 7.7 * 9.4in
Package Weight: 2.97kg/ 6.6lb (2972.6g/104.8oz)
Package List:
1 * Digital Storage Oscilloscope
2 * Oscilloscope Probe
1 * Oscilloscope Powerline
1 * Hantek Data CD
1 * USB Line
1 * BNC to BNC Wire