LaserSE

All Lasers in Life Science Industry info@laserse.com

Hantek DSO4102S Digital Multimeter Oscilloscope USB 100MHz 2 Channels 7″ 64K TFT Arbitrary Waveform Osciloscopio Logic Analyzer

  • Home
  • Hantek DSO4102S Digital Multimeter Oscilloscope USB 100MHz 2 Channels 7″ 64K TFT Arbitrary Waveform Osciloscopio Logic Analyzer
Sale!

Hantek DSO4102S Digital Multimeter Oscilloscope USB 100MHz 2 Channels 7″ 64K TFT Arbitrary Waveform Osciloscopio Logic Analyzer

$298.44

SKU: 2251832457976832 Category:

Description

  • Brand Name: Hantek
  • Certification: CE
  • DIY Supplies: ELECTRICAL
  • Origin: Mainland China
  • Model Number: DSO4102S
  • Record Length: 40K
  • Display Resolution: 800*480 Pixels
  • Display Size: 7 Inches & Above
  • Max Waveform Capture Rate: 30,000wfm/s
  • Band Width: 100-349MHz
  • IS Battery Demountable: No
  • Digital Channels: 2
  • Real Time Sampling Rate: 1GSa/S

Hantek DSO4102S Digital Multimeter Oscilloscope USB 100MHz 2 Channels 7″ 64K TFT Arbitrary Waveform Osciloscopio Logic Analyzer

2 Channel Digital Oscilloscope. 1 Channel Arbitrary/Function Waveform Generator. The Keys for oscilloscope and waveform generator is separated for convenient to operate it simultaneously. Oscilloscope: 100MHz Bandwidth, 1GSa/s Sample Rate. 25MHz Arbitrary waveform generator, 12 bits resolution, 200MHz DDS, 7 inch 64K color LCD display, Resolution 800×480.

Features:
2 channel digital oscilloscope + arbitrary/function waveform generator + synchronizing signal + external trigger.
The keys for oscilloscope and waveform generator is separated for convenient to operate it simultaneously.
Large and clear display (7 inch 64K color LCD display, Resolution 800×480), more clear and realistic waveform.
Oscilloscope: 1GSa/s Sample Rate, 100MHz Bandwidth, more than 20 kinds of auto measurement functions.
Powerful trigger function: edge, video, pulse, slope, over time, alternative.
Arbitrary/function waveform generator: 25MHz, 12 bits resolution, 200MHz DDS, arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC is easy to simulate transducer.
Integrated USB Host, Support USB disk storage, USB interface/SD card system update.

Note:
Hantek DSO4102S Digital Oscilloscope is for 3 years Warranty!
Please read the instruction manual data CD carefully to avoid injury and prevent damage to this product.

Specifications:

Model

DSO4102S

Oscilloscope

Sample Rate

Sampling Rate Range: 1GSa/s

Equivalent Sample Rate: 25GSa/s

Acquisition Modes

Normal

Normal data only

Peak Detect

High-frequency and randon glith capture

Average

Wavefom Average, selectable 4,8,16,32,64,128

Inputs

Inputs Coupling

AC, DC, GND

Inpits Impendance

1MΩ±2% 20pF±3pF

Probe Attenuation

1X, 10X

Supported Probe Attenuation Factor

1X, 10X, 100X, 1000X

Maximum Input Voltage

CAT I and CAT II: 300VRMS (10×)

CAT III: 150VRMS(1×);

Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.

Horizontal

Sample Rate Range

1GS/s

Waveform Interpolation

(sin x)/x

Record Length

40K

SEC/DIV Range

4ns/div to 40s/div

Sample Rate and

±50ppm(at over any ≥1ms time interval)

Delay Time Accuracy

Position Range

20ns/div to 80us/div; (-8div x s/div) to 40ms;

200us/div to 40s/div; (-8div x s/div) to 400s

Delta Time Measurement Accuracy
(Full Bandwidth)

Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200

Vertical

Vertical Resolution

8-bit resolution, all channel sampled simultaneously

Position Range

2mV/div to 10V/div

Bandwidth

100MHz

Rise Time at BNC( typical)

3.5ns

Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled

2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±1V

500mV/div to 2V/div, ±40V; 5V/div, ±50V

Math

+, -, *, /, FFT

FFT

Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;

1024 sample point

Bandwidth Limit

20MHz

Low Frequency Response (-3db)

≤10Hz at BNC

DC Gain Accuracy

±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;

±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div

DC Measurement Accuracy,
Average Acquisition Mode

When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div

Volts Measurement Repeatability, Average Acquisition Mode

Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

Trigger System

Trigger Types

Edge, Video, Pulse, Slope, Over time, Alternative

Trigger Source

CH1, CH2, EXT, EXT/5, AC Line

Trigger Modes

Auto, Normal, Single

Coupling Type

DC, AC, Noise Reject, HF Reject, LF Reject

Trigger Sensitivity
(Edge Trigger Type)

DC(CH1,CH2):

1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;

DC(EXT):

200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;

DC(EXT/5):

1V from DC to 100MHz;1.75V from 100MHz to 200MHz;

AC: Attenuates signals below 10Hz;

HF Reject: Attenuates signals above 80kHz;

LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz

Trigger Level Range

CH1/CH2: ±8 divisions from center of screen;

EXT: ±1.2V;

EXT/5:±6V

Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns

CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;

EXT: ± (6% of setting + 40mV);

EXT/5: ± (6% of setting + 200mV);

Set Level to 50%(typical)

Operates with input signals ≥50Hz

Video Trigger

Video Trigger Type

CH1, CH2: Peak-to-peak amplitude of 2 divisions;

EXT: 400mV;

EXT/5: 2V

Signal Formats and Field Rates, Video Trigger Type

Supports NTSC, PAL and SECAM broadcast systems for any field or any line

Holdoff Range

100ns ~ 10s

Pulse Width Trigger

Pulse Width Trigger Mode

Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse

Pulse Width Trigger Point

Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width

Pulse Width Range

20ns ~ 10s

Slope Trigger

Slope Trigger Mode

Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope

Slope Trigger Point

Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.

Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.

Less than: The oscilloscope triggers when the waveform slope is less than the set slope.

Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

Time Range

20ns ~ 10s

Overtime Trigger

Over Time Mode

Rising edge or Falling edge

Time Range

20ns ~ 10s

Alternative Trigger

Trigger on CH1

Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger on CH2

Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger Frequency Counter

Readout Resolution

6 digits

Accuracy (typical)

±30ppm (including all frequency reference errors and ±1 count errors)

Frequency Range

AC coupled, from 4Hz minimum to rated bandwidth

Signal Source

Pulse Width or Edge Trigger modes: all available trigger sources

The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.

Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.

Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.

Video Trigger mode: The Frequency Counter does not work.

Measure

Cursor Measurement

Voltage difference between cursors: V

Time difference between cursors: T

Reciprocal of T in Hertz (1/ΔT)

Auto Measuerment

Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time,

+Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid,

Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH,

FRF, FFR, LRR, LRF, LFR, LFF

Signal Source Mode

Waveform Impedance

DC-25MHz

Sample Rate

200MHzDDS

Output Waveform

Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC

Frequency Resolution

0.1%

Waveform Depth

2KSa

Vertical Resolution

12bit

Frequency Stability

<30ppm

Waveform Range

-3.5V~+3.5V

Output Impedance

50Ω

Output Current

50mA Ipeak=100mA

System BW

25M

Harmonic Distortion

-50dBc(1KHz),-40dBc(10KHz)

General Features

Display

Display Type

7 inch 64K color TFT (diagonal liquid crystal)

Display Resolution

800 horizontal by 480 vertical pixels

Display Contrast

Adjustable (16 gears) with the progress bar

Probe Compensator Output

Output Voltage( typical)

About 5Vpp into ≥1MΩ load

Frequency(typical)

1kHz

Power Supply

Supply Voltage

100-120VACRMS(±10%), 45Hz to 440Hz, CAT2

120-240VACRMS(±10%), 45Hz to 66Hz, CAT2

Power Consumption

<30W

Fuse

2A, T rating, 250V

Environmental

Temperature

Operating: 32 Fahrenheit to 122 Fahrenheit (0 to 50 Centigrade);

Nonoperating: -40 Fahrenheit to 159.8 Fahrenheit(-40 Centigrade to +71Centigrade)

Cooling Method

Convection

Humidity

+104 Fahrenheit or below (+40 Centigrade or below): ≤90% relative humidity;

106 Fahrenheit to 122 Fahrenheit (+41 Centigrade to 50 Centigrade): ≤60% relative humidity

Altitude

Operating: Below 3,000m (10,000 feet);

Nonoperaring: Below 15,000m(50,000 feet)

Mechanical

Package Size

Length 385mm, Width 200mm, Height 245mm

Weight

3.0KG(with Packing); 2.06KG(without Packing)

Material: ABS
Bandwidth: 100MHz
Plug Type: EU / US (Optional)
Power Supply: AC220V~240V 50Hz / AC100~120V 60Hz
Oscilloscope Probe Model: PP-150
Length of the Powerline: Approx. 150cm / 59.1in 
Length of the USB Line: Approx. 107cm / 42.1in
Length of the Probe Line: Approx. 130cm / 51.2in
Size of the Oscilloscope Body: Approx. 31.5 * 12 * 15cm / 12.4 * 4.7 * 5.9in (L * W * H)
Oscilloscope Weight: 2.06kg/ 4.6lb
Package Size: Approx. 38.5 * 19.5 * 24cm / 15.1 * 7.7 * 9.4in
Package Weight: 2.97kg/ 6.6lb  (2972.6g/104.8oz)

Package List:
1 * Digital Storage Oscilloscope
2 * Oscilloscope Probe
1 * Oscilloscope Powerline
1 * Hantek Data CD
1 * USB Line
1 * BNC to BNC Wire