Description
- Origin: CN(Origin)
- Certification: NONE
- Working Principle: Laser
- distance measurement: 60m
- Item: PLS-K-60
- decoration and construction contents: High-precision ranging
type1 distance measuring module ordinary version
type2 distance measuring module high temperature resistant version
type3 distance measuring module ordinary version USB
type4 distance measuring module high temperature version USB
type5 machine (normal version)
type6 machine (high and low temperature version)
Model model | PLS-K-60 |
Type | Single-point Phase laser distance measuring module |
Indoor RangeIndoor range | 0.03-60m |
Outdoor range @100Wlux Outdoor range | 0.03-10m |
Output frequencyoutput frequency | 2Hz |
Repeat accuracyaccuracy | 2mm |
Absolute accuracyAbsolute accuracy | ±2mm |
Resolutionresolution | 1mm |
Blind SpotBlind area | 3cm |
The light sourceLight | 635nm,<1mW,Red Laser,Second-class safety laser |
Communication InterfaceCommunication interface | UART TTL |
Serial port levelSerial level | VTTL=3.3V |
Operating temperatureOperating temperature | 0-40 ℃(Normal paragraph)-40- 55 ℃(High and low temperature section) |
Working voltageWorking voltage | DC 3.3 V |
Working currentWorking current | 80mA |
PowerPower | 0.27W |
Volumevolume | 50*26*14mm |
Weightweight | 10g |
1. Module Introduction
Laser distance measuring module is a high precision ranging module developed by our company.,Has the advantages of high measuring precision,High measurement speed,Simple installation and operation, etc.。It has been widely used in home decoration measurement,Industrial control and other fields。
2. Principle of Laser range measurement
time of flight method-Phase measurement principle。
3. Performance parameters
Measurement accuracy |
±2mm |
Working voltage |
DC2.5~3.3V |
The measured distance |
0.03-60m |
The measurement time |
0.1~3 seconds |
Laser class |
ⅡStage |
Laser type |
635nm,<1mw |
The volume of the module |
48*26*13mm |
Weight |
38g |
Operating temperature range |
0-40 ℃( 32-104 ℉ ) |
Storage Temperature range |
-25 C°~60 C°( -13~140 ℉ ) |
4. Interface
5. Power supply
PLS-K-60Working voltage range is DC 2.0V~3.3V,It is recommended to use3.3VOr3.0VDC power supply,During normal measurement, the current is100mA@3.3V, In order to ensure the stable operation of the module,Power transmission capacity needs300mAAnd above。
The power supply connection schematic figure 4-2As shown in, WhereP3.VIN For power input pin,P1.GNDFor the power supply ground。
6.
Communication configuration
Basic configuration of serial port of control terminal:
The baud rate:19200bps
Start:1Bit
Data bits:8Bit
Stop:1Bit
Check bits:No